3d printer calibration
When doing something on a 3d printer, most of the times you don’t need to do anything, but sometimes it is necessary to calibrate some stuff. Changing the hot-end, heat-bed will force you into doing that.
Extruder calibration
If you have a bowden setup, decouple the bowden tube from the extruder
M503 ; report the old M92 value
Say the old value is 400
M83 ; set extruder in relative mode
M302 ; report minimum extrusion temp (170)
M302 P1 ; enable cold extrusion
Place a dot mark on the filament some 12 cm an measure the start of the dot to the begin of the extruder, say 12.5 cm.
G1 E100 F100 ; extrude 10 cm of filament
Again measure the distance from the dot to the begin of the extruder, say 2.9 cm, and calculate the difference: 12.5 2.9 = 9.4 The new M92 value should be:
400*10/9.4 = 425.53
Setting the new M92
M92 e425.53
And storing and reviewing it with:
M500 ; Save settings to eeprom
M501 ; Set Active Parameters
M503 ; display current settings
Nozzle and bed temperature PID calibration
Nozzle PID calibration 8 times at 225°C:
M303 E0 S225 C8 ; extruder 0 at 225oC 8 times
This will at the end give the P, I and D values, store these with:
M301 P12.53 I0.71 D55.59
For the bed use bed use the next command:
M303 E-1 S60 C5 ; bed at 60oC 5 times
And store it with
.. code-block::
M304 P10.97 I1.01 D79.53
As a last step:
M500 ; Save settings to eeprom
M501 ; Set Active Parameters
M503 ; display current settings
And you are done.
Bed calibration with bl-touch
After changing the something to the bed it is necessary to change the M851 Z height. This is done in 15 simple steps:
G28 ; Home the printer
M851 Z0 ; Reset the Z offset
M500 ; Store active parameters
M501 ; Set active parameters
M503 ; Display active parameters
G28 Z ; Home Z axis
G1 F60 Z0 ; Move nozzle to the true 0 offset
M211 S0 ; Switch of soft end stops
Move bed slowly using a feeler gauge for example .2 mm, using the printer z-menu Take a note of the Z on the printer display and add feeler gauge size in this case .2 mm
M851 Z-2.80 ; the -2.8 is the achived z-offset, -2.6 on the printer and .2 from the feeler gauge
M211 S1 ; re-enable the soft end stops
M500 ; Store active parameters
M501 ; Set active parameters
M503 ; Display active parameters
And you are done.